Understanding and Estimating Pressure Drop
Pressure drop is the difference in pressure measured at two points in a hydraulic circuit. Every component in the circuit adds to it, including quick couplings, so it has to be accounted for in system design. This four-minute video explains what causes pressure drop, what happens when it is too high, and how to estimate it for Stucchi components using the pressure drop charts in the Stucchi catalog.
What This Video Covers
- 0:00 — Introduction
- 0:16 — What pressure drop is
- 0:30 — What happens when pressure drop is too high
- 1:30 — Factors that affect pressure drop
- 2:50 — How to read a Stucchi pressure drop chart
- 3:33 — More resources
What Happens When Pressure Drop Is Too High
- Reduced efficiency and performance. The system may not operate as intended, and components might not receive the power they need.
- Higher energy use and operating costs. Pumps have to work harder to compensate, which takes more power.
- Equipment failure. Undersized components create excessive turbulent flow, which stresses components and leads to premature failure.
- Safety hazards. Components that are not sized properly can put operators and people nearby at risk.
What Affects Pressure Drop
- Fluid viscosity. Thicker, more viscous fluids resist flow more, which raises pressure drop.
- Friction. Fluid loses energy as it rubs against the inner surfaces of hoses. This is specific to each system and its fluid passage geometry, and it changes with coupling series and size.
- Hose length and diameter. A longer hose means more pressure drop. A larger inner diameter lowers fluid velocity and reduces it.
- Fluid temperature. Temperature changes the viscosity of most fluids, which changes resistance to flow.
- Flow rate. More flow through the same size component increases pressure drop.
How to Estimate Pressure Drop for Stucchi Couplings
Each series page in the Stucchi catalog includes a pressure drop chart. To read it:
- Find your flow rate on the Y-axis.
- Draw a horizontal line across the chart to the curve for your coupling size.
- From that intersection, move straight down to read the pressure drop value.
Stucchi’s pressure drop charts were tested with ISO 32 weight oil at 40 °C. If your fluid has a different viscosity, a conversion factor may be needed.
You can find pressure ratings for all Stucchi components on each product page of our website and in our catalog.
More on Hydraulic Pressure Drop
Learn more with our free guide, Understanding Hydraulic Pressure Drop: Enhancing System Efficiency and Reliability.
Learn more about Stucchi’s Connect Under Pressure (CUP) technologies, with depressurizing quick couplers, multi-coupling plates, and auxiliary hydraulic solutions.
Frequently Asked Questions
What is pressure drop in a hydraulic system?
Pressure drop is the difference in pressure measured at two different points in a hydraulic circuit. All components in the circuit add to it, so it has to be considered in system design.
What happens if pressure drop is too high?
The system loses efficiency and performance, pumps work harder and use more energy, components can fail early from excessive turbulent flow, and improperly sized components can create safety hazards for operators and people nearby.
What causes pressure drop?
The main factors are fluid viscosity, friction against hose walls, hose length and inner diameter, fluid temperature, and flow rate.
How do I estimate pressure drop for a Stucchi coupling?
Use the pressure drop chart on the coupling’s series page in the Stucchi catalog. Find your flow rate on the Y-axis, draw a line across to the curve for your size, and read down to the pressure drop value. The charts were tested with ISO 32 weight oil at 40 °C, so a different viscosity may need a conversion factor.
Video Transcript
In this video, we’ll help you understand what pressure drop is and how to estimate it for Stucchi components.
Pressure drop is the difference in pressure measured at two different points in a hydraulic circuit. All components in the hydraulic circuit add to this pressure drop and have to be considered in system design.
There are many consequences when back pressure or pressure drop is too great. Reduced system efficiency and performance: when pressure drop in hydraulic hoses is not accounted for properly, the hydraulic system may not operate as intended and components might not receive the necessary power to perform optimally.
It can also increase energy consumption and operational costs. To compensate for high pressure drops, pumps in hydraulic systems often have to work harder, requiring more power. This increases energy consumption and leads to higher operating costs.
Equipment failures can also occur due to improper sizing or excessive pressure drop. Component stress and premature failure can occur when components are exposed to excessive turbulent flow in the system caused by undersizing. There can also be safety hazards for operators and people around these systems if components are not sized properly.
Many factors contribute to pressure drop, including the type of fluid and its viscosity. The medium’s viscosity is a measurement of the fluid’s resistance to flow. The higher the viscosity of a fluid, the greater the pressure drop. Thicker fluids, or those with higher viscosity, resist flow more than less viscous fluids, leading to higher pressure drops.
Another contributing factor is friction and hose wall interaction. As fluid rubs against the inner surfaces of the hoses, it loses energy, resulting in pressure drop. This varies by hydraulic system and fluid-passage geometry and changes with series and size.
Hose and assembly length and diameter can increase pressure drop. The longer the hose, the more pressure drop. Conversely, a larger inner diameter reduces fluid velocity and therefore decreases pressure drop in the hydraulic hose.
Fluid temperature directly affects the viscosity of most fluids, which impacts flow resistance and pressure drop. Flow rate also contributes to pressure drop. More flow through the same-size components increases pressure drop.
To estimate pressure drop at a given flow for Stucchi components, refer to the catalog series page; each series includes a posted pressure drop chart. First, find the flow rate on the Y-axis and draw a horizontal line across the chart to find the series size. Once the size curve is found, find that intersection and move vertically to read the pressure drop value.
Stucchi’s pressure drop charts were tested with 32 weight ISO oil at 40 °C. If you’re using a different viscosity for your medium, there may be a conversion factor needed.
For more information about pressure drop and how to estimate it for Stucchi components, visit this informative page on our website. Go to the Solutions tab and look for Understanding and Estimating Pressure Drop.
Note: this guide has moved since the video was made. It is now under Engineers & OEMs in the menu: Hydraulic Pressure Drop: What to Know.