Skip to main content
You are here:
Print

How To Connect / Disconnect Using the GR Series

The Stucchi GR Series multi-coupling plate connects multiple hydraulic and electrical lines at once, so hoses cannot be cross-matched. This video introduces the GR system and its components and shows how to connect and disconnect the two halves.

What This Video Covers

  • 0:04 — Introduction and where the GR Series is used
  • 0:28 — Why connecting multiple lines at once matters
  • 1:03 — Couplers and performance
  • 1:26 — What’s included
  • 1:37 — Connecting the plates
  • 2:19 — Disconnecting the plates

Summary Benefits of GR Multi-Plates

  • Allows the simultaneous connection and disconnection of up to 10 hydraulic and/or electrical lines
  • Simple single movement requiring minimal force to connect or disconnect
  • Auto-lock design prevents accidental disconnection
  • Circuit lines can have the same or different size couplers or media
  • Ideal for applications requiring leak-free connections, connecting with residual pressure, or when crossing connections causes damage or downtime

Where the GR Series Is Used

  • Agricultural
  • Mobile construction
  • Oil and gas
  • Industrial: anywhere you need to manage multiple lines during connection and disconnection

Why Connect Multiple Lines at Once

  • Connecting lines one at a time lets hoses be cross-matched, which can damage the hydraulic system, expose operators to unsafe working conditions and cause unscheduled downtime.
  • The GR Series connects multiple lines at the same time in a very safe manner, with an exact and precise connection for each hose.
  • It uses flat-face, connect-under-pressure couplers with higher working pressure and better flow characteristics than some other couplers, which reduces environmental impact and improves productivity and efficiency.

What’s Included

  • A fixed half, normally mounted to the machine
  • A mobile half, normally mounted to a work tool or implement
  • Protective accessories: a cap and a parking station

How to Connect the GR Plates

  1. Pull the trigger on the fixed half and move the handle to the unlocked position.
  2. Remove the protective cap.
  3. Remove the mobile half from its docking station.
  4. Align the pins so they mate into the fixed half bore.
  5. Pull the locking trigger to release the plate from the unlocked position, and move the handle to the connect position until you hear a click. The click means the connection is fully made.

How to Disconnect the GR Plates

  1. Pull the locking trigger and move the handle up.
  2. Remove the mobile half from the fixed half and place it in its docking station.
  3. Replace the cap on the fixed half to protect the couplings.

More Resources

See the GR Plate Series product page, browse all multi-coupling plates, or watch How to Connect and Disconnect Stucchi’s DP Series Multi-Plate. For help choosing a plate, contact your Stucchi representative.

Frequently Asked Questions

What does the GR Series multi-coupling plate do?

It connects multiple lines at the same time in one safe connection, with an exact and precise connection for each hose, instead of connecting couplers one at a time.

Why use a multi-coupling plate instead of single couplers?

When lines are connected one at a time, hoses can be cross-matched, which can damage the hydraulic system, expose operators to unsafe working conditions and cause unscheduled downtime.

What is included with the GR Series?

A fixed half that is normally mounted to the machine, a mobile half that is normally mounted to a work tool or implement, and protective accessories: a cap and a parking station.

How do you know the GR plate is fully connected?

Move the handle to the connect position until you hear a click. The click means the connection is fully made.

Video Transcript

In this video, we’re going to introduce the GR Series and all the components that come with the GR system, as well as show you how to connect and disconnect the two halves. The GR Series can be applied to many different industries, including agricultural, mobile construction, oil and gas, or industrial: anywhere that you need to manage multiple lines during the connection and disconnection process.

The GR Series is considered very safe and more efficient when connected, because it’s able to connect those multiple lines in one connection. In these applications, hoses can be cross-matched, which can cause damage to the hydraulic system, expose operators to unsafe working conditions, and cause unscheduled downtime. The GR Series can prevent these issues by connecting multiple lines at the same time in a very safe manner, while ensuring an exact and precise connection for each hose.

The GR Series uses a flat face coupler that is a connect-under-pressure style, and it also includes higher working pressure and better flow characteristics than some other couplers that you can choose. This is important because the coupler reduces the impact on the environment and also brings more productivity and efficiency to the user.

The GR Series includes a fixed half that is normally mounted to the machine, a mobile half that’s normally mounted to a work tool or implement, as well as protective accessories such as a cap and a parking station.

To connect the multi-coupling plate, first pull the trigger on the fixed half and actuate the handle to the unlocked position. Next, remove the protective cap. And now you can remove the mobile half from its docking station. When connecting the mobile half to the fixed half, first align the pins so that they mate into the fixed half bore. Now pull the locking trigger to release the plate from the unlocked position, and actuate the handle to the connect position until you hear a click. The click means that the connection is fully made.

To disconnect the plates, just do this process in the reverse order. So first, pull the locking trigger, actuate the handle up, and now you’re able to remove the mobile half from the fixed half plate and replace it into its docking station. Replace the fixed half cap for protecting the couplings, similar to how you connected the mobile half.